Your location:主页 > Product > Closed cooling tower >

BNX Counter Flow Serial Closed Circuit Cooling Tower

Closed Circuit Cooling Tower are routinely selected for numerous commercial and industrial process cooling applications.
 
Some examples include:
Water-source heat pumps
Cooling special fluids.
Self-contained cooling units
Compressor jacket cooling Intercooling, Aftercooling.
Chillers
Machine jacket cooling
Free cooling applications
Induction furances
Data centers
Consolidating multiple loads into a single cooling nuit
Hybrid evaporative/dry cooling
The closed circuit cooling tower advantage
 
Closed circuit cooling systems provide many operational and maintenance benefits to the user by keeping the process fluid in a clean, closed loop.
Protect process fluids from contamination
Maximize system efficiency by reducing fouling and scaling tendencies
Reduce system energy costs
Reduce system maintenance costs
The closed circuit cooling advantage
 
Vs. Cooling Tower+Heat Exchanger Combination
Closer approach to wet bulb and reduced fouling improve process efficiency
Vs.Air-Cooled Systems
10—20tClower process temperatures.less required space.and lower energy consumption.
Vs.Open Cooling Towers
Contaminant free,closed loop cooling significantly reduces process foulmg.ensurmg constant performance over time.
Vs.Once-Through Systems
Reduces environmental impact,saving up to 95% of the cooling water.
Rdduced Installed Cost And Space Requirements
Effectively combines the function of a cooling tower and heat exchanger into one pece of equipment.reduces required piping and system complexity
For BNX series counter flow type closed circuit cooling tower, the fresh air intakes from bottom air inlet, and will become saturated hot air mixed with spraying water as they flow in reverse direction. The heat will be exhausted out by fans,but the water will be collected to water basin for secondary spraying by its special designed drift eliminator. As no infill inside, BNX series cooling tower has much space to enlarge its coil unit heat rejection area, the structure is more compact and requires less footprint. Especially, its suitable to the fluid with high temperature.
 
Advantages:
1, No infill designed, more compact structure, lower profile, less installation
area required, and easy for transport and installation.
2,Suitable to severe environment as its structure much more close, which could prevent from sand and dust. So it widely used for casting workshop,mining factory etc.
3, Suitable to high temperature fluid, because hot spraying water will not distort PVC fill as no PVC fill designed.
4, Freezing resistance,because there is no PVC fill to slow down spraying water flow speed.
型号
MODEL
处理量
CAPACITY
(M3/h)
风机
FAN
水泵
WATER SPRAYING PUMP
接管口径
INLET/OUTLET DN(MM)
近似重量
WEIGHT
外形尺寸
DIMENSION
数量
QTY
功率
POWER(K/W)
单台风量
AIR VOLUME PER SET(M3/h)
数量
QTY
功率
POWER(K/W)
单台淋水量
WATER VOLUME PER SET(M3/h)
运输重量
SHIPPING
(KG)
运行重量
OPERATIONG
(KG)
总长
LENGTH
(MM)
总宽
WIDTH
(MM)
总高
HEIGHT
(MM)
BNX-10 12 1 1.5 18000 1 0.55 23 DN50 890 1660 1230 1150 3440
BNX-20 21 1 2.2 30000 1 0.75 28 DN50 1370 2480 1925 1150 3650
BNX-30 33 1 3 45000 1 0.75 28 DN50 1990 3620 1925 1840 3840
BNX-40 43 1 4 60000 1 1.1 45 DN80 2120 3790 1925 1840 4220
BNX-50 51 1 5.5 75000 1 1.5 65 DN80 2420 4490 2470 1840 4220
BNX-60 61 1 7.5 87000 1 1.5 65 DN80 2690 4760 2470 1840 4450
BNX-70 70 1 7.5 100000 1 2.2 84 DN100 3650 6080 2790 1840 4450
BNX-80 80 2 4 65000 1 2.2 84 DN100 4150 7480 3770 1840 4220
BNX-90 90 2 4 65000 1 2.2 84 DN100 4680 8010 3770 1840 4450
BNX-100 100 2 4 65000 1 2.2 84 DN125 5120 8450 3770 1840 4450
BNX-110 110 2 5.5 75000 1 3 120 DN125 5360 9430 3770 2200 4220
BNX-125 125 2 5.5 75000 1 3 120 2-DN100 5980 10050 3770 2200 4450
BNX-135 135 2 5.5 87000 1 4 170 2-DN100 6230 11270 4846 2200 4350
BNX-150 150 2 7.5 100000 1 4 170 2-DN100 6560 11590 4846 2200 4650
BNX-165 165 3 4 65000 1 4 170 2-DN100 7850 13730 5610 2200 4350
BNX-180 183 3 5.5 75000 1 4 170 2-DN125 8450 14330 5610 2200 4650
BNX-200 200 3 5.5 75000 1 4 170 4-DN80 9180 15380 6046 2200 4650
BNX-225 225 3 7.5 87000 1 5.5 230 4-DN80 9780 17340 7230 2200 4650
BNX-250 250 4 5.5 75000 2 3 120 4-DN100 10860 18520 7450 2200 4650
BNX-265 265 4 5.5 75000 2 4 170 4-DN100 11480 20880 9030 2200 4965
BNX-280 280 4 5.5 75000 2 4 170 4-DN100 11720 21120 9030 2200 4965

Notes:
1.Do not use for construction. This brochure includes data current at the time of publication which should be reconfirmed at the time
of purchase
2.All location dimensions for coil connections are approximate and should not be used for prefabrication of connecting piping.
3.Design conditions:wet bulb temperature 28.2℃,inlet water temperature 37℃,outlet water temperature 32℃

Scan QR code and share to wechat